Voltage - Frequency - Converter
for all worldwide voltages
Series: SFC 3 kVA ... 800 kVA 50 Hz > 60 Hz 60 Hz > 50 Hz
Appliances designed for the American line voltage (120/208 Volt, 60 Hz) which are used in the European power grid (230/400 Volt, 50 Hz) need a Voltage-Frequency Converter.
Application:
- Operation of import / export devices with different voltage and frequency
- Development
- Production
- Test Field
- Quality Assurance
CYSCO Voltage-Frequency Converter convert 50 Hz to 60 Hz and 60 Hz to 50 Hz and are available for all worldwide voltages.
Product overview
Information: Power grids in the USA
- All units are available also just as frequency converters or as only voltage converter .
By default the following versions are available:
AC-INPUT: 230 V, 50 Hz, 1-phase
AC-OUTPUT: 120 V, 60 Hz, 1-phase
Typ: | SFC 3 MM |
SFC 6 MM |
SFC 8 MM |
SFC 10 MM |
AC-Input | ||||
Voltage | 230 Volt, 1-phase |
|||
Frequency | 50 Hz |
|||
AC-Output | ||||
Voltage | 120 Volt |
|||
Frequency | 60 Hz |
|||
Output power | 3 kVA |
6 kVA |
8 kVA |
10 kVA |
Waveform | sinewave |
|||
Design | compact housing |
AC-INPUT: 120 V, 60 Hz, 1-phase
AC-OUTPUT: 230 V, 50 Hz, 1-phase
Typ: | SFC 3,5 MM-US |
SFC 5 MM-US |
SFC 8 MM-US |
SFC 10 MM-US |
AC-Input | ||||
Voltage | 120 Volt, 1-phase |
|||
Frequency | 60 Hz |
|||
AC-Output | ||||
Voltage | 230 Volt |
|||
Frequency | 50 Hz |
|||
Output power | 3,5 kVA |
5 kVA |
8 kVA |
10 kVA |
Waveform | sinewave |
|||
Design | compact housing |
AC-INPUT: 400 V, N, 50 Hz, 3-phase
AC-OUTPUT: 120 V, 60 Hz, 1-phase
Typ: SFC- | 5 TM |
8 TM |
10 TM |
12 TM |
15 TM |
20 TM |
30 TM |
AC-Input | |||||||
Voltage | 400 V, N, 3-phase |
||||||
Frequency | 50 Hz |
||||||
AC-Output | |||||||
Voltage | 120 V |
||||||
Frequency | 60 Hz |
||||||
Output power | 5 kVA |
8 kVA |
10 kVA |
12 kVA |
15 kVA |
20 kVA |
30 kVA |
Waveform | sinewave |
||||||
Design | compact housing |
AC-INPUT: 208 V, N, 60 Hz, 3-phase
AC-OUTPUT: 230 V, 50 Hz 1-phase
Typ: SFC- | 5 TM US |
8 TM US |
10 TM US |
12 TM US |
15 TM US |
20 TM US |
30 TM US |
AC-Input | |||||||
Voltage | 208 V, N, 3-phase |
||||||
Frequency | 60 Hz |
||||||
AC-Output | |||||||
Voltage | 230 V |
||||||
Frequency | 50 Hz |
||||||
Output power | 5 kVA |
8 kVA |
10 kVA |
12 kVA |
15 kVA |
20 kVA |
30 kVA |
Waveform | sinewave |
||||||
Design | compact housing |
AC-INPUT: 400 V, N, 50 Hz, 3-phase
AC-OUTPUT: 208 V, N, 60 Hz, 3-phase
Typ: SFC- | 5 TT |
8 TT |
10 TT |
12 TT |
15 TT |
20 TT |
30 TT |
40 TT |
AC-Input | ||||||||
Voltage | 400 V, N, 3-phase |
|||||||
Frequency | 50 Hz |
|||||||
AC-Output | ||||||||
Voltage | 120/208 V, N, 3-phase |
|||||||
Frequenz | 60 Hz |
|||||||
Output power | 5 kVA |
8 kVA |
10 kVA |
12 kVA |
15 kVA |
20 kVA |
30 kVA |
40 kVA |
Waveform | sinewave |
|||||||
Design | compact housing |
AC-INPUT: 208 V, N, 60 Hz, 3-phase
AC-OUTPUT: 400 V, N, 50 Hz, 3-phase
Typ: SFC- | 5 TT US |
8 TT US |
10 TT US |
12 TT US |
15 TT US |
20 TT US |
30 TT US |
40 TT US |
AC-Input | ||||||||
Voltage | 208 Volt, N, 3-phase |
|||||||
Frequency | 60 Hz |
|||||||
AC-Output | ||||||||
Voltage | 400 Volt, N, 3-phase |
|||||||
Frequency | 50 Hz |
|||||||
Output power | 5 kVA |
8 kVA |
10 kVA |
12 kVA |
15 kVA |
20 kVA |
30 kVA |
40 kVA |
Waveform | sinewave |
|||||||
Design | compact housing |
AC-INPUT: 400 V, N, 50 Hz, 3-phase
AC-OUTPUT: 480 V, N, 60 Hz, 3-phase
Typ: SFC- | 60 TT |
80 TT |
100 TT |
125 TT |
160 TT
|
AC-Input | |||||
Voltage | 400 Volt, N, 3-phase |
||||
Frequency | 50 Hz |
||||
AC-Output | |||||
Voltage | 480 Volt, N, 3-phase |
||||
Frequency | 60 Hz |
||||
Output power | 60 kVA |
80 kVA |
100 kVA |
125 kVA |
160 kVA
|
Waveform | sinewave |
||||
Design | switch-cabinet |
- Compact design
- Very high efficiency
- "Clean" and constant frequency sinewave output voltage
- State of the art, processor-controlled electronics with automatic self-test
- Any other global input and output voltage
e.g. 3AC 230/133 Volt, 415/240 Volt, 440/254 Volt, 480/277 Volt, 500/290 Volt or 600/347 Volt etc. - Custom output voltages, even several at a time
- Adaptation to different network systems
- Galvanic isolation between input and output
- Battery backup on power failure
- custom designs
Important note :
The operation of the engines is to recommend only limited, as they often have very high starting currents.
In general, the maximum possible power load must be taken into account in designing the dimensions of the SFC, even if this amount is reached only briefly.
CYSCO Voltage-Frequency-Converter are NOT frequency inverters which are used for electronic speed control of AC induction motors.
Different options and customized OEM versions on request.